Nextage Group 1300 075 075

Air curtains that keep the cold in with the door open.

Air curtains for store entrances, cool room doors, freezer openings, docks and service windows, sized to the opening and set up on site.

A white air curtain unit, as mounted over a door
A white air curtain unit, as mounted over a door
2.0 m/s
Jet speed at 150 mm above the floor, ASHRAE 90.1
20 degrees
Minimum discharge angle towards the opening
About 7 m
Highest openings the industrial families cover

Nextage supplies and manages the install of air curtains across Australia for store entrances, cool room and freezer doors, loading docks and service windows. An air curtain blows a sheet of air across an opening that has to stay open, so cold air stays in and warm air stays out without a door. Each unit is sized to the width and height of the opening and set up on site, because a jet that does not reach the floor at the right speed and angle does little.

The problem

  • Cool room doors propped open let cold air fall out across the floor.
  • Entrance doors held open let the air conditioning out and the weather in.
  • A curtain that was never set up after fitting runs all day and barely works.

What's included

  • A measure of each opening: width, height and what passes through it
  • The unit family and size that suits that opening
  • Mounting, power and controls organised with the electrician
  • Commissioning: jet speed and angle set on site with a meter
  • Before and after photos

Public liability insurance. Certificate on request.

Range

Air curtain families

A dock door and a service window are different problems, so the family is chosen for the opening.

01

Entrance, unheated

Air only, for air conditioned shopfronts, mounted over the door.

02

Entrance, heated

Electric or hot water heating in the air path, for cold climate entrances.

03

Cool room doors

Higher jet speed, stepless speed control and adjustable vanes, the retail back of house workhorse.

04

Freezer openings

Higher pressure units, sometimes two with opposed jets, for sub zero doors.

05

Industrial and docks

Three phase families for roller shutters, dock doors and warehouse openings up to about 7 m high.

06

Insect control

Built for the jet speeds NSF/ANSI 37 asks for at food premises openings.

07

Service windows

Compact units for pass throughs and small back doors.

08

Recessed

Units that sit in the ceiling void with only the grille showing.

09

Stainless and washdown

For wet, salty or food processing areas.

10

Vertical

Jamb mounted units for openings with no head height above.

Illustration: an open cool room door exchanging warm and cold air, beside the same door with an air curtain jet reaching the floor
Illustration: an open cool room door exchanging warm and cold air, beside the same door with an air curtain jet reaching the floor

Specification

What sets one up properly

The figures an air curtain is judged against.

The service page shows the readings from a cool room door we measured, and what changed once the jet was set.

Download the spec sheet (PDF)

Jet speed
At least 2.0 m/s at 150 mm above the floor (ASHRAE 90.1)
Angle
Discharge at least 20 degrees towards the opening
Test standards
ANSI/AMCA 220 or ISO 27327-1
Food premises
NSF/ANSI 37 jet speeds for insect control
Sizing
To the opening width and mounting height
Commissioning
Speed and angle set on site with a meter
Building code
Not named in NCC J5D5; the certifier decides

Supply and install

Supplied, ordered and fitted for you.

No products to order, fixings to buy or trades to chase. One call, and it arrives fitted.

Tell us the site and roughly how many. We come back to you within 2 business days.

  1. We measure

    A site walk sets what goes where, and how many.

  2. We order

    The right product, size and quantity, delivered to site.

  3. We organise

    Access, inductions and timing around your trading hours.

  4. Installed by licensed trades, photographed by us

    Installed by licensed trades we manage, with before and after photos when it is done.

Often fitted in the same visit

A good fit

  • Cool room and freezer doors that stay open while staff work
  • Store entrances held open in trading hours
  • Docks, roller shutters and service windows
  • One door, or the same unit across a whole fleet

Not a fit

  • An opening that can simply be kept shut with a self closing door
  • Meeting NCC J5D5 on its own: air curtains are not named in it, so ask your certifier

Photos

An air curtain, measured

An air curtain over a cool room door, and the readings taken at that door with and without it running.

An air curtain mounted over a cool room door in a bottle shop, the door standing open onto shelving inside the cool room
An anemometer on a speckled floor reading 2.09 metres a second and 18.6 degrees
An anemometer display reading 0.73 metres a second and 9.8 degrees, beside a measuring tape
An anemometer held up at shelf height reading 0.04 metres a second and 5.1 degrees

FAQ

About air curtains

What does an air curtain do?

It blows a sheet of air across an open doorway so cold air stays in and warm air stays out, without a door being shut. It suits openings that have to stay open while people and stock move through.

How do you size an air curtain?

To the width of the opening and the mounting height, so the jet still reaches the floor. ASHRAE 90.1 asks for at least 2.0 m/s at 150 mm above the floor with the discharge angled at least 20 degrees towards the opening.

Does an air curtain meet the NCC?

NCC J5D5 lists airlocks, self closing doors, rapid roller doors, revolving doors and the like. Air curtains are not named in it, so your certifier decides whether one is accepted.

Can one go on a freezer door?

Yes, with a higher pressure family built for sub zero openings, sometimes two units with opposed jets, and a plan for where the moisture goes.

Which brand do you fit?

The unit is chosen for the opening from the families on this page, and the proposal names the model.

Do you supply air curtains for warehouse and loading dock doors?

Yes. The industrial families cover roller shutters, dock doors and warehouse openings up to about 7 m high. They run on three phase power and the fixing is engineered for the opening, so each door is measured first.

Do air curtains keep flies out?

Only a unit built for it. NSF/ANSI 37, the standard for air curtains at food premises openings, sets a jet speed of about 8.13 m/s at a service door and 3.05 m/s at a customer entrance. A comfort unit runs well under that, so tell us if the brief came from a food safety audit or a pest report.

Related

Often runs alongside

Refrigeration & door energy efficiency

Refrigeration & door energy efficiency

Aerofoil blades on refrigeration cabinets and air curtains at cool room and entry doors. Measured on site before capital is committed, then staged across the estate.

Read more
Open refrigerated wine case in a bottle shop

Energy efficiency

Aerofoils on open refrigerated cases: what they do, and why the saving has to be measured

How Aerofoil blades keep cold air in open multideck cases, and why the saving should be measured on your own cases before a fleet retrofit.

Guide · 3 min read ·

Read the guide
Illustration: an open refrigerated display cabinet fitted with Aerofoil shelf edge blades, with a close up of the blade profile and the airflow it holds against the case face

Energy efficiency

Aerofoils or fridge doors: the comparison that decides an open case retrofit

Doors cut more at the cabinet but shift load to store air conditioning, need upkeep and measurably cut sales. How the two compare, with sources.

Guide · 7 min read ·

Read the guide
Air curtain mounted above a cool room door

Energy efficiency

Air curtains at cool room and entry doors: what they do, and why the saving has to be measured

How an air curtain cuts cold air loss at cool room and store entry doors, why it has to be set up for the opening, and why to measure first.

Guide · 3 min read ·

Read the guide
LED strip lighting fitted along retail shelving

Energy efficiency

Climate reporting for retailers: what store energy data does AASB S2 need?

Group 2 climate reporting starts for years from 1 July 2026. Who is caught, what Scope 1 and 2 mean at a store, and how Scope 2 is worked out per site.

Guide · 5 min read ·

Read the guide
Open refrigerated wine case in a bottle shop

Energy efficiency

What does the HFC refrigerant phase down mean for store refrigeration?

The 2026 HFC quota cut, the proposed GWP 150 limit for new cold chain uses from 2028, which gases are under pressure, and what a store fleet can do now.

Guide · 5 min read ·

Read the guide

Doors open, cold getting out?

Tell us the store and the openings. We'll measure them and come back to you.

Call 1300 075 075 Start with one site